Вопрос :
After performing User Calibration with the Open Short and Load+ my YBA250 scale shows only 27 dB instead of the expected 54 dB line near the bottom of the screen when the load is attached. Why?
Ответ :
The YBA 250 Measurement is set to Cable Loss instead of Return Loss, which is why the indicated reading is one-half the expected answer. Set the YBA250 to Return Loss.
Эти часто задаваемые вопросы относятся к
Серия приборов не найдена
Прибор:
Идентификатор часто задаваемых вопросов 55186